20% OFF shipping at azure.archi on orders over $79 + up to 10% OFF products
azure.archi
home > EASYGEN 8406-120 Woodward EGCP-2 Datasheet & Technical Manual > EASYGEN 8406-120 Woodward EGCP-2 Datasheet & Technical Manual
download picture
EASYGEN 8406-120 Woodward EGCP-2 Datasheet & Technical ManualWoodward 8406 120 EGCP 2 Series Generator Controller Configured for multi genset synchronization, automatic start stop sequencing, and real time load sharing across generator networks, the Woodward 8406 120 (8406 120 Digital Engine Generator Controller) provides direct physical electrical execution. Hardware Specifications Parameter Specification Model 8406 120 (EGCP 2 Series, Rev G) Brand Woodward Origin United States Weight 4. 2 kg (7. 81 lbs
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 8406-120 EGCP-2 Series Generator Controller

Configured for multi-genset synchronization, automatic start/stop sequencing, and real-time load sharing across generator networks, the Woodward 8406-120 (8406-120 Digital Engine/Generator Controller) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 8406-120 (EGCP-2 Series, Rev G)
Brand Woodward
Origin United States
Weight 4.2 kg (7.81 lbs nominal shipping weight)
Dimensions 358 mm (W) x 282 mm (H) x 69 mm (D) (14.1 in x 11.1 in x 2.7 in)
Operating Temp -20 deg C to 70 deg C (-4 deg F to 158 deg F)
Storage Temp -40 deg C to 105 deg C (-40 deg F to 221 deg F)
Relative Humidity 95% at 60 deg C, non-condensing
Power Supply Input 9 to 32 VDC continuous (12 VDC or 24 VDC nominal engine battery)
Voltage Inputs (PT) 150 to 300 VAC RMS, 50/60 Hz sensing range
Current Inputs (CT) 5 A RMS nominal (5 Amp AC maximum)
Internal Processor 32-bit microprocessor architecture
Display Interface Panel-mounted dual backlit LCDs (8 lines x 20 characters)
Serial Communication RS-485 interface via Modbus RTU and Woodward ServLink
Certifications CE, UL, CSA

Actuator Loop Feedback Response & Power Management

The controller serves as the primary processing module for up to 8 parallel-connected generator sets. It samples high-voltage potential transformer (PT) lines up to 300 VAC alongside 5 A current transformer (CT) inputs, computing real-time phase match vectors and slip frequencies to coordinate dead-bus closing states and automatic breaker transitions.

The 32-bit internal processor regulates speed and voltage output lines by sending dynamic fuel and excitation corrections to downstream governor and automatic voltage regulator (AVR) actuators. This actuator loop feedback response mitigates voltage and frequency oscillations during stepped load changes, while integrated software routines run continuous checks for reverse power conditions, over/under frequency variables, and local engine safety parameters.

Frequently Asked Questions

Q: Does the 8406-120 generator controller support Remove and Insert Under Power (RIUP) or hot-swap maneuvers? A: No. This panel-mounted instrument requires dedicated point-to-point wiring harnesses for raw AC phase monitoring, current transformers, and logic lines. Disconnecting or connecting terminals while the DC bus or current transformer paths are energized can induce extreme open-circuit current transformer overvoltages, permanent circuit breakdown, and uncommanded breaker actuation.

Q: How can configuration data and engine variables be tracked remotely from a centralized SCADA system? A: The device features an integrated RS-485 network port running standard Modbus RTU protocol registers. This interface links real-time diagnostic parameters, kilowatt (kW) distribution values, and fault alarms to supervisory hosts, running alongside a dedicated Woodward ServLink connection for engineering terminal calibration.

Q: What happens to the fuel governor loop if the magnetic pickup sensor line drops out during operation? A: The module executes built-in safety protection algorithms. If the speed frequency signal collapses while the main breaker remains shut, the controller registers an instantaneous engine alarm state, cutting output signals to the actuator drive to kill fuel delivery and prevent an unmonitored runaway condition.

Field Installation Guidelines

  • Panel Mount Alignment: Insert the controller into an engineered dashboard or enclosure door cutout. Fasten all perimeter mounting clamps to the rated torque settings to ensure the rear terminal array is isolated from moisture ingress and high vibration.
  • Current Transformer Isolation Block: Always pipe the 5 A current transformer loops through an external, shorting terminal block before routing wires into the controller casing. Never open-circuit active current transformer secondary lines while the generator shaft is rotating.
  • Low-Voltage Cable Separation: Route all low-level signal cabling, including RS-485 networks, actuator drive outputs, and magnetic pickup wires, inside dedicated shielded conduits. Isolate these lines from raw AC generator lines and heavy engine cranking circuits to prevent high-frequency electromagnetic field distortion.

EASYGEN 8406-120 Woodward EGCP-2 Datasheet & Technical Manual

Item no : 16687251135
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 2 - Jul 7

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches