20% OFF shipping at azure.archi on orders over $79 + up to 10% OFF products
azure.archi
home > 1762-L24BWA Allen-Bradley MicroLogix 1200 Datasheet & Technical Manual > 1762-L24BWA Allen-Bradley MicroLogix 1200 Datasheet & Technical Manual
download picture
1762-L24BWA Allen-Bradley MicroLogix 1200 Datasheet & Technical ManualAllen Bradley 1762 L24BWA MicroLogix 1200 Controllers The Allen Bradley 1762 L24BWA, also cataloged as the 1762 L24BWA Programmable Controller, operates as a dedicated hardware component for discrete logic execution and digital signal processing within MicroLogix 1200 platforms. The device integrates 14 digital input channels and 10 relay output channels into a single chassis powered via a 120 240 VAC source. Physical signal processing paths
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Allen-Bradley 1762-L24BWA MicroLogix 1200 Controllers

The Allen-Bradley 1762-L24BWA, also cataloged as the 1762-L24BWA Programmable Controller, operates as a dedicated hardware component for discrete logic execution and digital signal processing within MicroLogix 1200 platforms. The device integrates 14 digital input channels and 10 relay output channels into a single chassis powered via a 120/240 VAC source. Physical signal processing paths accommodate 4 high-speed discrete inputs for rapid transient detection alongside 10 standard inputs, executing deterministic logic switching routines based on hardwired program execution.

Hardware Specifications

Parameter Specification
Model 1762-L24BWA
Brand Allen-Bradley
Origin United States
Weight 0.91 kg (2.0 lbs shipping weight)
Dimensions 11 cm x 9 cm x 8.7 cm
Operating Temp 0 to 55 deg C
Power Consumption 70 VA
Line Voltage 100 to 240 VAC (-15%, +10%) at 47 to 63 Hz
Discrete Inputs 14 total (10 Standard Inputs, 4 Fast Inputs)
Input Circuit Type 24 VDC sink/source
Nominal Impedance 3.3 kiloohms (inputs 0-3), 2.7 kiloohms (inputs 4 and above)
On-State Voltage 14-26.4 VDC at 55 deg C (inputs 0-3), 10-26.4 VDC (inputs 4 and above)
Off-State Leakage Current 1.5 mA maximum
Discrete Outputs 10 Relay Outputs
Status Indicators Integrated LED array for I/O and CPU status

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The execution parameters of this controller interact with external communication topologies and expansion mechanics to determine complete I/O density scaling. Local hardware limits expand via 1762 series expansion modules, extending physical channel allocation while maintaining local bus timing profiles. For integration within high-level Profinet / EtherNet/IP deterministic networks, peripheral bridge modules transform local serialized communication into packet-synchronized industrial ethernet protocols, stabilizing data execution cycles across distributed supervisory networks without expanding CPU cycle times.

Frequently Asked Questions

Q: What are the functional constraints when driving high-frequency inductive loads with the relay outputs?

A: The relay contacts are mechanical components subject to physical wear. Operating inductive loads without surge suppression accelerates contact erosion; external surge suppressors must be applied parallel to the load to stabilize long-term operation.

Q: How do the input impedance differences between channels 0-3 and channels 4 and above affect field device wiring?

A: Channels 0-3 have a nominal impedance of 3.3 kiloohms to accommodate fast input transient pulses, requiring a stable 14-26.4 VDC signal for an on-state definition. Channels 4 and above utilize 2.7 kiloohms impedance, reducing the minimum on-state voltage requirement to 10 VDC.

Field Installation Guidelines

  • DIN-Rail and Panel Mounting: Secure the module to a 35 mm DIN-rail or mount directly to a backplate using the integral mounting holes. Ensure vertical orientation to allow correct convection airflow through the chassis cooling vents.
  • AC Power Supply Connections: Route the 120/240 VAC line power directly to the designated termination points. Use appropriate gauge wire rated for 70 VA loads and enforce separation between AC supply lines and low-voltage DC input signals.
  • Input and Output Wiring Separation: Maintain strict segregation between the 24 VDC sink/source field inputs and the internal relay contact lines to prevent electrical cross-talk or induced noise transients.
  • Grounding Requirements: Establish a low-impedance ground path by connecting the functional earth terminal directly to the central panel enclosure ground bus bar before activating primary electrical systems.

1762-L24BWA Allen-Bradley MicroLogix 1200 Datasheet & Technical Manual

Item no : 47934534523
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 5 - Jul 10

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches