Shopping security
The Yokogawa PW481-10, also cataloged as the PW481-10 Power Supply Module, operates as a dedicated hardware component for supplying regulated DC power to I/O modules and node units within CENTUM VP and ProSafe-RS networks.
| Parameter | Specification |
|---|---|
| Model | PW481-10 (S2 Style) |
| Brand | Yokogawa |
| Origin | Japan / Singapore |
| Weight | 1.04 kg (2.29 lbs) |
| Dimensions | 130 mm x 30 mm x 100 mm |
| Operating Temp | 0 to +60 deg C |
| Power Consumption | 120 W |
| Input Voltage Range | 100-120 V AC (50/60 Hz nominal) |
| Output Voltage | 24 V DC regulated |
| Output Current Capacity | 2.5 A continuous (Up to 5 A peak dynamic limit) |
| Power Conversion Efficiency | >80% typical |
| Circuit Protection | Overvoltage, overload, and short-circuit protection |
| Cooling Method | Natural convection |
| Storage Temperature | -20 to +70 deg C |
| Relative Humidity Bounds | 10 to 90% RH, non-condensing |
| Regulatory Compliance | CE, UL, RoHS |
The electrical converter processes line power via its 100-120 V AC interface to supply clean internal bus currents. To support downstream field devices operating over a 4-20 mA HART loop protocol layer, the internal circuitry enforces strict channel-to-channel isolation metrics that decouple high-voltage utility lines from the low-voltage logic core. The DC voltage regulations utilize active overvoltage filters to isolate switching noise spikes. This isolated framework eliminates the risk of field-side common-mode noise passing through the power rails into adjacent ESB or ER bus nodes, preserving the overall data resolution within the system rack.
Q: How does the internal short-circuit protection handle a direct short on the 24 V DC rail? A: The module activates built-in electronic shutdown circuits immediately when an overload or short-circuit condition crosses the safety trip boundary. The unit remains in a protected hiccup or cut-off state until the physical field wiring fault is resolved, resetting automatically thereafter.
Q: What are the primary ventilation requirements for the PW481-10 when mounted in high-density configurations? A: The module utilizes natural convection cooling to maintain operational temperature bounds between 0 and +60 deg C. It must be installed into a standard chassis orientation that leaves adjacent ventilation slots unblocked to prevent local heat concentration.
Q: Can this power supply interface simultaneously with both ESB and ER bus node variations? A: Yes. The rear backplane plug layout matches standard Yokogawa node structures, allowing the unit to slide into the dedicated power supply bay of either an ESB bus or an ER bus node assembly.