20% OFF shipping at azure.archi on orders over $79 + up to 10% OFF products
azure.archi
home > 80105 HIMA Planar4 Relay Output Module | New & Original Stock > 80105 HIMA Planar4 Relay Output Module | New & Original Stock
download picture
80105 HIMA Planar4 Relay Output Module | New & Original StockHIMA 80105 Planar4 Relay Output Module The HIMA 80105, also cataloged as the 80105 Relay Output Module, operates as a dedicated hardware component for safe relay based signal switching within Planar4 safety system platforms. Hardware Specifications Parameter Specification Model 80105 Brand HIMA Origin Germany Weight Standard Planar4 module weight criteria Dimensions Standard Planar4 rack slot footprint Operating Temp 0 deg C to +60 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HIMA 80105 Planar4 Relay Output Module

The HIMA 80105, also cataloged as the 80105 Relay Output Module, operates as a dedicated hardware component for safe relay-based signal switching within Planar4 safety system platforms.

Hardware Specifications

Parameter Specification
Model 80105
Brand HIMA
Origin Germany
Weight Standard Planar4 module weight criteria
Dimensions Standard Planar4 rack slot footprint
Operating Temp 0 deg C to +60 deg C
Power Consumption 2-3 W
Output Type Relay contacts
Number of Outputs 2-4 channels (variant dependent)
Rated Control Voltage 24 V DC control supply
Switching Capacity Up to 250 V AC / 5 A
Isolation Voltage 1500 V AC
Reaction Time 10 ms
Relative Humidity 5% to 95% non-condensing
Safety Certification SIL 3 / SIL 4 (IEC 61508 compliant)
Mounting Style Rack-mounted in Planar4 backplane

Fail-Safe State Execution and Safety Architecture

The HIMA 80105 functions as an electromechanical switching layer designed to maintain a default fail-safe state execution configuration during internal logic trips or macro power blackouts. To comply with SIL 3 / SIL 4 safety system architectures, the mechanical contacts are arranged to guarantee positive, open-circuit isolation whenever control logic loops register an emergency shutdown (ESD) condition. The 1500 V AC dielectric isolation barrier separates high-voltage field switching transients from the logic bus matrix. This hardware-driven separation prevents external field line short-circuits from injecting destructive overvoltages into adjacent sub-rack monitoring electronics or compromising triple modular redundancy (TMR) safety loops.

Frequently Asked Questions

Q: How do the mechanical relay elements inside the 80105 handle inductive load spikes?

A: The internal contacts have an isolation rating up to 1500 V AC, but high inductive counter-electromotive forces (back-EMF) from inductive loads can cause contact degradation or welding. External RC snubbers or surge suppression networks must be implemented in parallel across the field load to mitigate arcing and preserve the safety loop life expectancy.

Q: Can the 80105 module be hot-swapped while the field outputs are actively energized?

A: No. Hot-swapping the module while the backplane bus or field loops are carrying an active electrical load is restricted. Removing the module under load can generate inductive arcing across the rear backplane pin connections, which risks damaging the solid-state control drivers.

Field Installation Guidelines

  • Sub-Rack Alignment and Seating: Guide the module straight along the Planar4 sub-rack card guides. Ensure that the rear connector blocks line up exactly with the backplane pin field before applying final force to lock the faceplate retention fasteners.
  • Inductive Load Suppression: Install external suppression components (diodes for DC loads, varistors or RC networks for AC loads) directly at the terminals of the field device. This step prevents high-voltage transient feedback from entering the module through the field wiring.
  • Shield Grounding Matrix: Connect all external field cable shielding to the designated enclosure grounding bus panel using a low-impedance copper conductor. Do not reference field shields to the local backplane terminal common line.
  • Cable Pathway Separation: Maintain separate physical cable routes within the control panel wire ducts. Low-voltage 24 V DC control loop signaling lines must not run parallel to high-capacity 250 V AC switching loops to avoid inductive noise coupling.

80105 HIMA Planar4 Relay Output Module | New & Original Stock

Item no : 72974504900
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 5 - Jul 10

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches