20% OFF shipping at azure.archi on orders over $79 + up to 10% OFF products
azure.archi
home > Juniper ACX-MIC-4COC3-1COC12CE Interface Card > Juniper ACX-MIC-4COC3-1COC12CE Interface Card
download picture
Juniper ACX-MIC-4COC3-1COC12CE Interface Card[shortdesc] Multirate Circuit Emulation MIC 4 Port Channelized OC3 STM1 (down to DS0) or 1 Port Channelized OC12 STM4 (down to DS0) CE MIC for ACX4000 [ shortdesc] [properties] Properties Juniper ACX MIC 4COC3 1COC12CE Description Multirate Circuit Emulation MIC, 4 Port Channelized OC3 STM1 (down to DS0) or 1 Port Channelized OC12 STM4 (down to DS0) CE MIC, for ACX4000 Product Family ACX4000 Series Product Type Modular Interface Card Ports Four OC3
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
[shortdesc]
  • Multirate Circuit Emulation MIC
  • 4 Port Channelized OC3/STM1 (down to DS0) or 1 Port Channelized OC12/STM4 (down to DS0)‚ CE MIC
  • for ACX4000
[/shortdesc]

[properties]

Properties Juniper ACX-MIC-4COC3-1COC12CE
Description Multirate Circuit Emulation MIC, 4 Port Channelized OC3/STM1 (down to DS0) or 1 Port Channelized OC12/STM4 (down to DS0)š CE MIC, for ACX4000
Product Family ACX4000 Series
Product Type Modular Interface Card
Ports Four OC3/STM1 ports

Rate-selectable using one of the following rates:

4-port OC3/STM1

1-port OC12/STM4

One channelized OC12/STM4 port (down to DS0)
Weight (lb/kg) 1.67 lb (0.76 kg)
Power requirement without PoE 2.21 A @ 12 V (26.56 W)

[/properties][specifications]

Specifications ACX-MIC-4COC3-1COC12CE
Configurations SONET or SDH is configurable on a MIC level
SONET channelization:

- 4 OC3 channel

- 336 DS1 channels

- 2016 DS0 channels (combination of nxDS0)

SDH channelization:

- 4 STM1 channel

- 252 E1 channels

- 2016 DS0 channels (combination of nxDS0)
Software Features Per-MIC SONET/SDH framing

Internal and loop clocking

Encapsulations:

- Pseudo Wire Emulation Edge-to-Edge (PWE3) Architecture (RFC 3985)

- Requirements for Pseudo-Wire Emulation Edge-to-Edge (PWE3) (RFC 3916)

- Structure-Agnostic Time Division Multiplexing (TDM) over Packet (SAToP) (RFC 4553)

- Structure-Aware Time Division Multiplexed (TDM) Circuit Emulation Service over Packet Switched Network (CESoPSN) (RFC 5086)

- Pseudowire Emulation Edge-to-Edge (PWE3) Control Word for Use over an MPLS PSN (RFC 4385)
Operating temperature -40° to 149° F (-40° to 65° C)
Humidity 95% RH noncondensing
Safety Approvals CAN/CSA-C22.2 No. 60950-1
UL 60950-1
EN 60950-1
IEC 60950-1CB Scheme
EN 60825-1
EMC AS/NZS CISPR22 Class A
EN55022 Class A
VCCI Class A
FCC Part 15 Class A
IECS-003 Issue 4
BSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions
KN 22, Class A
CISPR 32/EN55032: 2012 European Radiated Emissions Class A
EN-61000-4-6 Low Frequency Common Immunity
EN-61000-4-11 Voltage Dips and Sags
CISPR 24/EN55024 Information Technology Equipment Immunity Characteristics
ETSI (European Telecommunications Standardization Institute) EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements
ETSI EN 300 019-2-1 (2000) Storage, Class T1.2
ETSI EN 300 019-2-2 (1999) Transportation, Class T2.3
ETSI EN 300 019-2-4 (2003) Stationary Use at Non-Weather Protected Locations, Class 4.1
ETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment
NEBS SR-3580 NEBS Criteria Levels (Level 3 Compliance)
GR-63-CORE: NEBS, Physical Protection
GR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)
GR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)
Telecomm Compliance T1 and XDSL Interfaces FCC Part 68 (T1 Only)
Industry Canada CS-03
JATE Green Book
E1 Interface TBR 12/13
ACA TS016
G.703
RTTE Directive 1995/5/EC
Device management: NETCONF, CLI, SNMP v1/v2/v3
End-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)
Device and service-level fault management
Device and service-level performance management
Metro Ethernet Forum (MEF) MEF CE2.0 compliant

[/specifications][accesories] [/accesories]

Juniper ACX4000 Universal Metro Router is a 2.5 U, actively cooled access router that is environmentally hardened for field deployment. This versatile, high-performance mobile access platform runs on the Junos operating system.

Juniper ACX-MIC-4COC3-1COC12CE Interface Card

Item no : 99879543114
sold recently : Login >>
US$ 10829.47
Pay in 4 interest-free payments of $2707.37 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 5 - Jul 10

Enjoy 20% off shipping

US$ 10829.47

1-11

US$ 9746.52

12-35

US$ 7580.63

36-59

US$ 6497.68

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

ICED OUT
ICED OUT

US$ 24.00

Min. order: 1 piece

4.2 (59 reviews)

Sold : Login>>

Related Searches