20% OFF shipping at azure.archi on orders over $79 + up to 10% OFF products
azure.archi
home > autoclave 18 liters class b with usb green > autoclave 18 liters class b with usb green
download picture
autoclave 18 liters class b with usb greenGreen 18 liter Class B Autoclave with USB Warranty details Safety The cycle does not start if the door is not properly closed. The automated double hydraulic interlocking safety device prevents the door from opening while the chamber is under pressure. Safety valves prevent pressure generator and camera. A safety thermostat prevents overheating in the chamber and generator. An automatic safety lock prevents accidental opening of the door during the
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Green 18-liter Class B Autoclave with USB

Warranty details

Safety
- The cycle does not start if the door is not properly closed.
- The automated double hydraulic interlocking safety device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process. The protector automatically cuts off electrical power if there is a short circuit somewhere or the power supply is not very stable.
- Failure alarm indicates a failed cycle and a detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or too full.


Technical specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- Chamber dimensions: 247 x 350 mm
- Tray size: 192 x 285 mm
- Circuit breaker: F16A / 400V
- 2000W
- Rated power: 1500 VA
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- External dimensions: 490 x 455 x 600 mm
- Net weight: 47 kg
- Maximum noise level: <70 dB
- Atmospheric pressure: 76 kPa / 106 kPa

Maintenance and error message guide for your sterilizer

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Safety valve
- Ventilation grill
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 2 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain pipes
- Door seal
- Instruction manual

Regulations
- 93/42 / EEC Medical Devices Directive.
- 97/23 / EEC Pressure Equipment Directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilizers used for the treatment of medical materials.

Autoclave process step-by-step
1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer (sold separately).

4. Power on: the main switch is located on the front, bottom right of the device. Once switched on, the LCD screen will light up and the basic autoclave operating symbols, such as door position, water level, sterilization program, date, time, will light up.

5. Remove the top cover then fill the distilled water tank. If an audible signal sounds, it means that you have exceeded the permitted water level in the tank. Drain the excess water until the alarm turns off.

6. Preparation of materials for sterilization: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization pouches. These must not be in contact. Check that all instruments are properly placed, so that no water remains in hollow parts. Do not overload instrument trays and do not place them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Caution: ensure the door is properly closed, otherwise the autoclave will not be able to operate.

9. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

10. End of the sterilization cycle.
Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Caution: Use plastic tongs to remove the instruments.

IMPORTANT: Do not reuse wastewater after emptying the tank.

 

It is important to keep the original packaging in case of after-sales service.

autoclave 18 liters class b with usb green

Item no : 4016472875
sold recently : Login >>
US$ 13982.50
Pay in 4 interest-free payments of $3495.62 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 28 - Aug 2

Enjoy 20% off shipping

US$ 13982.50

1-11

US$ 12584.25

12-35

US$ 9787.75

36-59

US$ 8389.50

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.