home > Digital DC Voltmeter PCE-DC 25 > Digital DC Voltmeter PCE-DC 25
download picture
Digital DC Voltmeter PCE-DC 25DESCRIPTION Voltmeter with Bluetooth interface Current measurement 0 1000 A AC DC Temperature measurement NCV test Clamp opening 34 mm (1. 3") Measuring rate of 3 Hz Optionally expandable with Rogowski coil for 3000 A AC Automatic switch off The voltmeter has a measuring range of 0 1000 A AC DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1. 2") can be connected to the
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

DESCRIPTION

Voltmeter with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz /
Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off

The voltmeter has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.

In addition to current measurement, the voltmeter can also measure voltages from 0… 1000 V AC/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.

The voltmeter can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values ​​can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions.

HIGHLIGHTS

- Measuring range 0 ... 1000 A AC/DC
- Bluetooth interface
- Inrush current measurement
- Not Connected Voltage function
- LC colour display
- Optionally with ISO certificate

SPECIFICATION

DC voltage
Measuring range 600.0 mV DC
Resolution 0.1 mV DC
Accuracy ±(0.5 % + 8 digits)
Measuring range 6.000 V DC
Resolution 0.001 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V DC
Resolution 0.01 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V DC
Resolution 0.1 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V DC
Resolution 1 V
Accuracy ±(1.5 % + 5 digits)
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
AC voltage
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(1.5 % + 5 digits)
Peak value (PEAK) accuracy ±10 %
Peak value (PEAK) response time 1 ms
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Low pass filter (LowZ)
(50 ... 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 300.0 V AC
Resolution 0.1 V
Accuracy ±(3.0 % + 40 digits)
Input impedance <300 kΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
AC with DC voltage
(50 ... 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(2.5 % + 20 digits)
Input impedance >10 MΩ
Direct current
Measuring range 600.0 A DC
Resolution 0.1 A DC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A DC
Resolution 1 A DC
Accuracy ±(2.8 % + 5 digits)
Overvoltage protection 1000 A DC
Alternating current
(50 ... 60 Hz)
Measuring range 600.0 A AC
Resolution 0.1 A AC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A AC
Resolution 1 A AC
Accuracy ±(2.8 % + 5 digits)
Overload protection 1000 A AC/DC
Flexible clamp meter
(50 ... 400 Hz)
Measuring range 30.00 A AC
Resolution 0.01 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 300.0 A AC
Resolution 0.1 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 3000 A AC
Resolution 1 A AC
Accuracy ±(3.0 % + 5 digits)
Overload protection 3000 A AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Resistance
Measuring range 600.0 Ω
Resolution 0.1 Ω
Accuracy ±(1.0 % + 10 digits)
Measuring range 6.000 kΩ
Resolution 0.001 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 kΩ
Resolution 0.01 kΩ
Accuracy ±(1.5 % + 5 digits)


Measuring range 600.0 kΩ
Resolution 0.1 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 6.000 MΩ
Resolution 0.001 MΩ
Accuracy ±(2.5 % + 5 digits)
Measuring range 60.00 MΩ
Resolution 0.01 MΩ
Accuracy ±(3.5 % + 10 digits)
Overvoltage protection 1000 V AC/DC


Continuity test
Signal <50 Ω
Overvoltage protection 1000 V AC/DC
Diode test
Test current <1.5 mA
Maximum tension when open
circuit
3.3 V DC
Frequency measurement
Measuring range 9.999 Hz ... 99.99 kHz
Resolution 0.01 ... 10 Hz
Accuracy ±(1.2 % + 5 digits)
Overvoltage protection 1000 V AC/DC
Sensitivity >5 Vrms with one duty cycle
from 20 ... 80 %
Duty cycle
Measuring range 10.0 ... 90.0 %
Resolution 0.1 %
Accuracy ±(1.2 % + 8 digits)
Pulse range 40 Hz ... 10 kHz
Pulse amplitude ±5 V (0.1 ... 100 ms)
Capacity
Measuring range 60.00 nF
Resolution 0.01 nF
Accuracy ±(4.0 % + 20 digits)
Measuring range 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6.000 µF
Resolution 0.001 µF
Accuracy ±(3.0 % + 8 digits)


Measuring range 60.00 µF
Resolution 0.01 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 600.0 µF
Resolution 0.1 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6000 µF
Resolution 1 µF
Accuracy ±(5.0 % + 8 digits)
Measuring range 60.00 mF
Resolution 0.01 mF
Accuracy ±(5.0 % + 20 digits)
Measuring range 100.0 mF
Resolution 0.1 mF
Accuracy ±(5.0 % + 20 digits)
Overvoltage protection 1000 V AC/DC
Temperature measurement
(Thermocouple Type K)
Measuring range -40 ... 600.0 °C
Resolution 0.1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range 600 ... 1000 °C
Resolution 1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range -40 ... 600.0 °F
Resolution 0.1 °F
Accuracy ±(1.5 % + 9 digits)
Measuring range 600 ... 1800 °F
Resolution 1 °F
Accuracy ±(1.5 % + 9 digits)
Overvoltage protection 1000 V AC/DC
The accuracy refers to the measuring device without temperature probe.
Specifications refer to a stable ambient condition of ±1 °C.
If the measurement lasts for a long time, the measured value increases by 2 °C
Further specifications
Clamp opening
34 mm / 1.3"
NCV >150 V AC
Display LC colour display
Display when measuring range exceeded "OL" (overload)
Measuring rate 3 measured values per second
Interface Bluetooth
Operating conditions 5 ... 40 °C / 41 ... 104 °F
<80 % RH non-condensing at
31 °C / 87 °F linearly decreasing to 50 % RH
non-condensing at 40 °C / 104 °F
Storage conditions -20 ... 40 °C / -4 ... 140 °F <80 % RH
non-condensing
Maximum working height 2000 m / 7000 ft
Power supply 3 x 1.5 V AAA batteries
Auto power off Switched off, 15, 30, 45, 60 minutes
Dimensions 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5"
Weight 365 g / 12.8 oz

DELIVERY SCOPE

1 x Voltmeter PCE-DC 25
1 x Pair of test leads
1 x Type K thermocouple
1 x Thermocouple adapter
3 x 1.5 V AAA batteries
1 x Transport bag
1 x Instruction manual
Downloads

PDF Specification Sheet - Download Here

Digital DC Voltmeter PCE-DC 25

Item no : 32967925271
sold recently : Login >>
US$ 360.00
Pay in 4 interest-free payments of $90.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 23 - Jul 28

Enjoy 20% off shipping

US$ 360.00

1-11

US$ 324.00

12-35

US$ 252.00

36-59

US$ 216.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches