Shopping security
The ProSoft MVI56E-MNET, also cataloged as the MVI56E-MNET Enhanced Network Interface Module, operates as a dedicated hardware component for Modbus TCP/IP Client/Server data conversion within Allen-Bradley ControlLogix platforms.
| Parameter | Specification |
|---|---|
| Model | MVI56E-MNET |
| Brand | ProSoft Technology (Belden ProSoft) |
| Origin | United States |
| Weight | 0.25 kg (0.57 lbs) |
| Dimensions | 3.3 cm x 14.7 cm x 14.0 cm (1.3 in x 5.8 in x 5.5 in) |
| Operating Temp | 0 deg C to 60 deg C (32 deg F to 140 deg F) |
| Storage Temp | -40 deg C to 85 deg C (-40 deg F to 185 deg F) |
| Power Consumption | Backplane powered, 800 mA at 5 VDC / 3 mA at 24 VDC |
| Ethernet Port | 1 x 10/100 Mbps Base-T RJ45 port |
| Memory Capacity | 5000 words (16-bit registers) |
| LED Indicators | Battery Status (ERR), Application Status (APP) |
| Configuration Interface | ProSoft Configuration Builder (PCB) / CIPconnect |
| Processor Compatibility | ControlLogix V 10 or higher |
| Tariff Code | 8537101190 (also classified under 8517620050) |
The module interfaces directly with standard 1756 ControlLogix backplanes, running concurrent Modbus TCP/IP Client and Server software stacks via a single RJ45 interface. The communication processor routes network data packages straight into an internal database containing 5000 16-bit registers.
By eliminating standalone serial-to-ethernet bridges, the hardware achieves low protocol conversion latencies. It integrates into the host controller memory maps using standard Add-On Instructions (AOI) or sample ladder logic. The internal memory layout matches legacy MVI56 parameter profiles, enabling backward compatibility for drop-in physical replacement without requiring complete application code overhauls.
Q: Does the MVI56E-MNET module support Remove and Insert Under Power (RIUP) actions? A: Yes. The electrical interface is compliant with 1756 ControlLogix chassis hot-swap standards, allowing live module replacement while backplane power is active. However, removing the module instantly drops all active Modbus TCP/IP sockets and halts asynchronous backplane block transfers.
Q: How is configuration data extracted or updated on the module over the plant network? A: The module supports CIPconnect, which enables ProSoft Configuration Builder software running on a network PC to bridge through the ControlLogix processor. This permits remote configuration downloads, configuration uploads, and diagnostic access without requiring a direct connection to the module's local port.
Q: Can this module maintain configuration variables if the chassis experiences a total power outage? A: Yes. Configuration parameters, network tables, and operational profiles are saved directly to internal non-volatile memory arrays. Onboard battery status is actively tracked by the ERR LED to warn of physical cell degradation affecting volatile register backup.
Ships within 48 hours · Estimated delivery Jul 2 - Jul 7